Krete-Chemical 870

technical data sheet

DESCRIPTION AND RECOMMENDED USES: 100% solids, Dura-Coat Krete-Chemical 870 is a solvent free, high functionality Novolac Epoxy coating ambient-temperature curing. It is designed particularly as protection coating for concrete highly aggressive chemical immersion and spills service Dura-Coat Krete-Chemical 870 is convenient-to-use, non-sagging with excellent high mechanical strength.

  • It can be applied up to 40 mils without slump
  • Ideally suited for concrete protection for corrosion
  • Suitable for and abrasion protection
  • Suitable for immersion and non-immersion service.

 

Application areas

Packages

Technical data

Maximum Temperature (Dependent on service)Wet Service | Dry Service65°C | 85°C149°F | 185°F
Chemical ResistanceWater | Alkalis | Inorganic Acids | Organic Acids | Organic SolventsExcellent | Excellent | Excellent | Excellent | Excellent
Solids by Volume 100%
Mixed Density1.4
Shore D Durometer Hardness(ASTM D 2240)84
Pot life35 MIN / KG at 72ºF
Vertical SAG Resistance at 21°C (70°F) and 1mm (40mils)No sag
Coverage for 7.5Kg kit57sf @40mils5.32m² @1mm
Mix Ratio2:1 by weightBase: Activator
ColorGray as standard. Blue and Red optional. Other colors contact the manufacture
Shelf life (unopened containers)3 years at 55-95ºF (13-35ºC)

Application sheet

Surface Preparation
Proper surface preparation is critically important for the long-term performance of the Dura-Coat Krete-Chemical 870. The prepared concrete surface must be structurally sound, free from all contaminants and roughened to an >ICRI CSP 3 profile (similar to #60 grit sandpaper). If using with Dura-Coat Krete-Seal 800, surface may be damp, but not wet i.e. no free-standing water. Dura-Coat Krete- Chemical 870 can be applied on damp concrete without using Dura-Coat Krete-Seal 800. A vapor barrier (Krete-Seal 800) is required for slab on grade application. If no vapor barrier is present, check for vapor transmission.

Surface Cleaning & Profiling Methods
Hydro-Blasting                      Scarifying
Steel Shot-Blasting               Dry Abrasive Blasting

Mixing
Thoroughly mix Activator into Base with mixing stick or drill with low-speed mixing blade scraping sides and bottom of container or mixing board. Mix by weight 1-part Base to 1-part Activator. Mix thoroughly to produce an even colored and streak-free material. THINNING: Never thin.

Application
Application temperature range 10°C (50°F)-32°C (90°F) (substrate).
Dura-Coat Krete-Chemical 870 may be applied by notched squeegee, spray system, brush, or roller.
Brush: medium to stiff bristle of sufficient quality that bristles do not pull out and stick in coating (epoxy glued bristles are best). Trim or tape to <1” nap.
Roller: use good quality 1/8” nap.
For maximum protection against immersion or spills, a 2-coat system is recommended.
To avoid sagging on vertical surfaces the maximum wet film thickness should be between 500 μm-1000 μm (20-40 mil) per coat.

Curing schedule

16°C (60°F)25°C (77°F)32°C (90°F)
Tack Free4 hours2 hours1 hour
Light Load12 hours6 hours3 hours
Overcoat End16 hours10 hours5 hours
Full Load24 hours12 hours6 hours
Full Chemical48 hours24 hours12 hours

Clean Up
Tools must be immediately cleaned after usage by using industrial alkaline detergent.

Safety
Before using any products, review the appropriate Safety Data Sheet (SDS) or Safety Sheet for your area. Follow standard confined space entry and work procedures, if appropriate.

download pdf

Download PDF (MSDS)