Industrial Floor 600

technical data sheet

DESCRIPTION AND RECOMMENDED USES: 100% solids, Dura-Coat Industrial floor 600 is a solvent free, Epoxy coating ambient-temperature curing. It is designed particularly as protective coating for concrete floors (or equivalent). Dura-Coat Industrial Floor 600 is convenient-to-use, self-leveling with excellent traffic resistance and high mechanical strength.

  • Easy to apply and quick back in service
  • Ideally suited for concrete protection
  • Suitable for abrasion protection
  • Suitable for high traffic

Application areas

Packages

Technical data

Maximum Temperature (Dependent on service)Wet Service | Dry Service50°C | 60°C122°F | 140°F
Chemical ResistanceWater | Alkalis | Inorganic Acids | Organic Acids | Organic SolventsExcellent | Excellent | Good | Good | Good
Solids by Volume 100%
Mixed Density1.25
Shore D Durometer Hardness(ASTM D 2240)82
Pot life25 MIN / KG at 72ºF
Vertical SAG Resistance at 21°C (70°F) and 0.635mm (25mils)No sag
Coverage for 10L kit 108sf@40mils10m²@1mm
Mix Ratio2:1 by weightBase: Activator
ColorGrey, green, red, orange, blue and yellow
Shelf life (unopened containers)3 years at 55-95ºF (13-35ºC)

Application sheet

Surface Preparation
Proper surface preparation is critically important for the long-term performance of the Dura-Coat Industrial Floor 600. The prepared concrete surface must be structurally sound, free from all contaminants and roughened to an >ICRI CSP 3 profile (similar to #60 grit sandpaper). If using with Dura-Coat Krete-Seal 800, surface may be damp, but not wet i.e. no free-standing water. Dura-Coat Industrial Floor 600 can be applied on damp concrete without using Dura-Coat Krete-Seal 800. A vapor barrier (Krete-Seal 800) is required for slab on grade application. If no vapor barrier is present, check for vapor transmission.

Surface Cleaning & Profiling Methods
Hydro-Blasting                   Scarifying
Steel Shot-Blasting            Dry Abrasive Blasting

Mixing
Thoroughly mix Activator into Base with mixing stick or drill with low speed mixing blade scraping sides and bottom of container or mixing board. Mix by Weight 2-part Base to 1-part Activator. Mix thoroughly to produce an even colored and streak-free material. THINNING: Never thin.

Application
Application temperature range 10°C (50°F)-32°C (90°F) (substrate).
Dura-Coat Industrial Floor 600 may be applied by notched squeegee, spray system, brush, or roller.
Brush: medium to stiff bristle of sufficient quality that bristles do not pull out and stick in coating (epoxy glued bristles are best). Trim or tape to <1” nap.
Roller: use good quality 1/8” nap.
For maximum protection against immersion or spills, a 2-coat system is recommended.
To avoid sagging on vertical surfaces the maximum wet film thickness should be between 500 μm-1000 μm (20-40 mil) per coat.

Curing schedule

16°C (60°F)25°C (77°F)32°C (90°F)
Tack Free6 hours3 hours2 hours
Light Load18 hours10 hours6 hours
Overcoat End24 hours16 hours8 hours
Full Load36 hours24 hours12 hours
Full Chemical72 hours36 hours18 hours

Clean Up
Tools must be immediately cleaned after usage by using industrial alkaline detergent.

Safety
Before using any products, review the appropriate Safety Data Sheet (SDS) or Safety Sheet for your area. Follow standard confined space entry and work procedures, if appropriate.

download pdf - english

Download PDF (MSDS) - english

download pdf - español

Download PDF (MSDS) - español

download pdf - português

Download PDF (MSDS) - português