High Temperature Structural Putty 2000

technical data sheet

DESCRIPTION AND RECOMMENDED USES: 100% solids, Dura-Coat High Temperature Structural Putty 2000 is a solvent free, high functionality Novolac Epoxy coating ambient-temperature curing. It is designed particularly as a rebuilding material for metals in highly aggressive chemical and temperature immersion service Dura-Coat High Temperature Structural Putty 2000 is convenient-to-use, non-sagging with excellent high temperature resistant and high mechanical strength. It is able to withstand up to 230°C continuous operation and up to 280°C intermittently.

  • It can be applied up to 500 mils without slump
  • Ideally suited for restoration cladding material for corrosion
  • Suitable for corrosion and abrasion protection
  • Suitable for immersion and non-immersion service

Application areas

Packages

Technical data

Maximum Temperature (Dependent on service)Wet Service | Dry Service230°C | 280°C446°F | 536°F
Chemical ResistanceWater | Alkalis | Inorganic Acids | Organic Acids | Organic SolventsExcellent | Excellent | Excellent | Excellent | Excellent
Solids by Volume 100%
ViscosityPaste
Mixed Density1.8
Shore D Durometer Hardness(ASTM D 2240)85
Pot life60 MIN / KG at 72ºF
Vertical SAG Resistance at 21°C (70°F) and 1 mm (40mils)No sag
Coverage for 10Kg kit60sf@40mils5.6m²@1mm
Mix Ratio2:1 by weightBase: Activator
ColorGrey as standard. Blue and Red optional. Other colors contact the manufacture
Shelf life (unopened containers)3 years at 55-95ºF (13-35ºC)

Application sheet

Surface Preparation
Proper surface preparation is critical to the long-term performance of this product. The exact requirements for surface preparation vary with the severity of the application, expected service life, and the initial substrate conditions. Minimum preparation is mechanical preparation St2/St3. Optimum preparation will provide a surface thoroughly cleaned of all contaminants and roughened to an angular profile between 75-125 μm (3-5 mil). This is normally achieved by initial cleaning and degreasing and then abrasive blasting to a cleanliness of Near White Metal (Sa.21/2), followed by removal of residual abrasive blast residues from the surface to be coated.

Mixing
Thoroughly mix Activator into Base with mixing stick or drill with low speed mixing blade scraping sides and bottom of container or mixing board. Mix by Weight 2-parts Base to 1-part Activator. Mix thoroughly to produce an even colored and streak-free material. THINNING: Never thin.

Application
Use heavy plastic squeegee or putty knife. Work material into profile of substrate to achieve maximum adhesion and to remove any entrapped air. Contour to correct form with putty knife or plastic applicator. If mold or form is used, coat its surface with a release agent to prevent adhesion of the material. Machining is possible using carbide tipped tools. Grinding is possible if done within 14 hours of application at 77ºF, 25ºC (add 1-1/2 hour for each 10ºF below 77º, subtract 1 hour for each 10º above 77ºF). Large holes and cracks can be bridged with glass or metal cloth.

Application Temperature: Keep between 55 to 95ºF (17 to 35ºC). Substrate: keep between 45 to 105ºF (7 to 40ºC). the difference in temperature of the substrate and the material should never exceed 10ºF, 5ºC. Substrate shall be a minimum of 5ºF (3ºC) above dew point. Do not apply if relative humidity exceeds 90%. If necessary, heat the metal prior to surface preparation using electric heater or heat lamp. Never use gas, oil, or kerosene heaters as they will leave a greasy residue on metal surface. For best results keep all material in warm area overnight (75ºF+) for ease of mixing.

Curing schedule

* For enhanced performance, post cure for 2 hours at 80°C (176°F) and 3 hours at 150°C (302°F)

16°C (60°F)25°C (77°F)32°C (90°F)
Tack Free1.5 hours1 hour45 mins
Light Load3 hours2 hours1.5 hours
Overcoat End3 hours2 hours1.5 hours
Full Load12 hours6 hours4 hours
Full Chemical36 hours24 hours18 hours

Clean Up
Tools must be immediately cleaned after usage by using industrial alkaline detergent.

Safety
Before using any products, review the appropriate Safety Data Sheet (SDS) or Safety Sheet for your area. Follow standard confined space entry and work procedures, if appropriate.

download pdf

download pdf (msds)